Labmedics supply platelet technologies that have revolutionized platelet function testing in clinical and research laboratories. Providing the most comprehensive platelet tests available from any one company, CHRONO-LOG® Platelet Aggregation and Secretion methodologies have been reliable tools in the diagnosis of platelet function defects, monitoring of anti-platelet drugs and assisting researchers in developing new therapies.
Hemostasis
Chrono-log
Celebrating 50 YEARS in the platelet testing field, Chrono-log was one of the first companies to manufacture the Platelet Aggregometer based on the Born method of measuring platelet aggregation in Platelet-Rich-Plasma [PRP] samples. Chrono-log has continued to specialize in Platelet Function Testing and was the first company to produce the Lumi-Aggregometer. Lumi-Aggregation, the measurement of ATP Release from the dense granules, provides the ability to perform a Secretion Study simultaneously with platelet aggregation in the same test sample.
Products
Reagents
CHRONO-LUME
Reagent for measurement of ATP release. Each vial contains 0.2 mg luciferin, 22,000 units d-luciferase plus magnesium sulfate, human serum albumin, stabilizers and buffer. Kit includes 4 vials of CHRONO- LUME plus a vial of lyophilized adenosine 5' triphosphate for use as an ATP Standard. Performs 50 to 100 tests in PRP or Whole Blood samples.
TO ORDER
Ristocetin CoFactor Assay
RISTOCETIN COFACTOR ASSAY KIT (von Willebrand Factor Assay)
For use in the quantitative determination of Factor VIII Ristocetin Cofactor Activity in citrated plasma. The following Materials included provide volumes sufficient to run 15 determinations: Ristocetin, 7.5 mg/vial; Lyophilized Human Platelets, 6 mL; von Willebrand Reference Plasma, Normal, 1.0 mL; von Willebrand Reference Plasma, Deficient, 0.5 mL; Tris Buffered Saline (TBA) 12 mL.
TO ORDER
LYOPHILIZED HUMAN PLATELETS 6mL, TRIS BUFFERED SALINE 12mL
For use in the quantitative determination of Factor VIII Ristocetin Cofactor Activity in citrated plasma. Each vial provides 6 mL of Platelets following reconstitution with Tris Buffered Saline (TBS) for performing up to 15 determinations.
TO ORDER
HEMOSTASIS REFERENCE PLASMA ABNORMAL 1mL
For use as an Abnormal Reference Plasma in the quantitative determination of Factor VIII Ristocetin Cofactor Activity in citrated plasma. Each vial contains 1.0 mL of dried plasma prepared from a pool of Normal Human Plasma. All analytes are adjusted to be in the Abnormal Range.
TO ORDER